BioAir TopSafe Drucken E-Mail
 

Microbiological Safety Cabinet 

    Fully EN12469 certified by Tüv
     Hamburg (Class II Type A2; Class I
     pending)
    State of the art microprocessor
     control system
    Main switch w/removable key
    Soft touch keyboard
    Bar graph for exhaust and downflow
     airflow conditions permanent display
     (Class II)
    Bar graph for exhaust air flow
     conditions permanent display
     (Class I)
    Alarms for low air flow and wrong
     front window position
    Sloped front and back wall for the
      most comfortable access
    Front access for filter maintenance
     and service
    C-shaped support stand for the
     easiest one man installation
     procedure
    Easy retrofit option kits

   Article No.: 14267 (Model 1.2) & 14291 
     (Model 1.5)
 

  The Top Safe Cabinets are supplied in three different sizes (1.2 mt, 1,5 mt). These last generation Microbiological Safety Cabinets have been certified according to the most stringent safety standards
(EN 12469 : 2000). The internal design, the air flow aerodynamics and monitoring, the built-in safety devices and the very accurate manufacturing, guarantees the highest performances at the most stringent safety levels, as specified by EN 12496 : 2000 standard and have been tested by the most prestigious European certification bodies for Safety Cabinets.
 
    Fully EN12469 certified by Tüv
     Hamburg (Class II type A2)
    Controls comfortably located at eye
     level
    Fan speed and aeraulic controlled by
     Microprocessor
    Three operating modes: normal, stand-
     by, calibration
    High speed rinse at start up
    Self calibration and internal Watch dog 
     cycle before “SAFE” condition is
     reached
    Visual display of “SAFE” conditions and
     “UNSAFE” conditions
      (LED and bar graph)
    Elapsed time meter
    Microprocessor control with following
     specifications:
          Alarms. Multilevel alarms, with
           redundancy functions.
          Permanent display of working
           conditions.
          Highest air flow stability both in
          case of transitional disturbances or to
          progressive filter clogging
         Continuous monitoring of front
          barrier air flow for the highest
          operator safety
         Low barrier alarm
         Power failure alarm
    Volt-free contact for remote monitoring
     of exhaust fan.
    Automatic reset of initial conditions in  
     case of power failure
    C-shaped support stand for the easiest
     one man installation procedure

 

   
    Sloped front design for the highest
     operational comfort. Sloped back side of
     the working chamber for the best down
     flow distribution (cabinet carcass
     EN12298 tested and certified for air
     tightness)
    Utilities inlets from the top of the
     cabinet.
    Stainless Steel internal surfaces with 2B
     finishing (including spillage tray). Solid
     work surface (3 sections) and special
     designed front grill.
    Exhaust grill (Class I) with high
     aerodynamic efficiency for a reduced
     turbulence exhaust air pattern inside the
     cabinet
    Comfortable 200mm front opening
    Easy to install retrofit options through
     lateral sides.
    Exposed exhaust Hepa filter for easy
     visual integrity check.
    H14 class High Efficiency Particulate Air
     filters with 99.999% efficiency on
     .3micron particles (most penetrating
     particle diameter) (EN1822-1 and EN
     13091:1999 tested and certified)
    Both exhaust and main filters (Class II
     type A2) are equipped with a micromesh 
     membrane located downstream which
     acts as airspeed equalizer expansion
     plenum, as well as a clear indicator of
     filter damages.
    Filter change and maintenance from the
     front of the cabinet.
    Exhaust transitions easily installable.
    Anti-blow-back valve available as add-on
     option
    Key operated. The key can be removed
     when the unit is in SAFE mode, in order
     to avoid unwanted operation. In case of
     power failure, the cabinet is re-set to
     original working conditions.
    Self calibration cycle performed when
    cabinet is switched on.
    High speed rinse and set up cycle
     performed, before reaching the SAFE
     operating mode.

   
    Visual display of SAFE conditions. Pre-
     warning before actual alarm conditions
     are reached (visual and acoustic alarms)
    Soft touch control with keys for standard
     service utilities. Interconnected UV and
     fluorescent lights.
    For Class II type A2 models, the exhaust
     and recirculating flow rates ensure 25 air
     changes/min in the working area (30%
     70% split)
    For Class II type A2 models, the front
     barrier air speed is ≥ 0.5mt/sec
    For Class I model, the total exhausted
     air flow ensures a minimum average
     front speed ≥ 0.7m/sec
    Aperture protection Factor (Apf) ≥ 1.5 x
     10 exp 5
    Cleanability Index CC grade.(EN 12296
     tested and certified)
    Light intensity on work surface > 900
     lux.
    Noise level ≤ 60dB(A) 1.2 mt Model
     (ISO 11201, ISO 4871 and ISO EN 3744
     tested and certified)
    Work surface displacement (vibration)
     <0.005mm RMS between 20Hz and
     20,000Hz (ISO 5349 tested and certified)
    230V, 50Hz
    Max power (for each power point)
     3Amps.
    Microprocessor equipped with analogical
     watch dog.
    CE certification according to Machinery
     Directive 89/392/EEC, 91/368/EEC,
     93/44/EEC 93/68/EEC.

 

 